Honeywell 4820i Scanner User Manual


 
5 - 5
Intercharacter, Interfunction, and Intermessage
Delays
Some terminals drop information (characters) if data comes through too quickly.
Intercharacter, interfunction, and intermessage delays slow the transmission of
data, increasing data integrity.
Each delay is composed of a 5 millisecond step. You can program up to 99
steps (of 5 ms each) for a range of 0-495 ms.
Intercharacter Delay
An intercharacter delay of up to 495 milliseconds may be placed between the
transmission of each character of scanned data. Scan the Intercharacter
Delay barcode below, then scan the number of milliseconds and the SAVE bar-
code using the Programming Chart inside the back cover of this manual.
To remove this delay, scan the Intercharacter Delay barcode, then set the num-
ber of steps to 0. Scan the SAVE barcode using the Programming Chart inside
the back cover of this manual.
Note: Intercharacter delays are not supported in USB serial emulation.
User Specified Intercharacter Delay
An intercharacter delay of up to 495 milliseconds may be placed after the trans-
mission of a particular character of scanned data. Scan the Delay Length bar-
code below, then scan the number of milliseconds and the SAVE barcode using
the Programming Chart inside the back cover of this manual.
1 2345
Intercharacter Delay
Prefix Scanned Data Suffix
Intercharacter Delay