Honeywell 7820 Barcode Reader User Manual


 
42
TROUBLESHOOTING GUIDE
SYMPTOMS POSSIBLE CAUSE(S) SOLUTION
The unit powers
up, but does not
scan and/or
beep.
Scanning a particular
symbology that is not
enabled.
UPC/EAN, Code 39, Interleaved
2 of 5, Code 93, Code 128 and
Codabar are enabled by default.
Verify that the type of bar code
being read has been selected.
The scanner has been
configured for a
character length lock,
or a minimum length
and bar code being
scanned does not
satisfy the configured
criteria.
Verify that the bar code that is
being scanned falls into the
criteria.
(Typical of Non-UPC/EAN
codes. The scanner defaults to
a minimum of 4 character bar
code.)
The unit scans
a bar code, but
locks up after
the first scan
(blue LED stays
off).
The scanner is
configured to support
some form of host
handshaking but is not
receiving the signal.
If the scanner is setup to support
ACK/NAK, RTS/CTS,
XON/XOFF or D/E, verify that
the host cable and host are
supporting the handshaking
properly.
The unit scans,
but the data
transmitted to
the host is
incorrect.
The scanner’s data
format does not match
the host system
requirements.
Verify that the scanner’s data
format matches the format
required by the host. Make sure
that the scanner is connected to
the proper host port.