Honeywell Mark III Network Router User Manual


 
HONEYWELL Aerospace Electronic Systems Page 53
Use or disclosure of information on this page is subject to the restrictions on the title page of this document.
5.4 Environmental Specifications
The following DO-160D categories will be used for the MARK III:
Temperature and Altitude (DO-160D Section 4.0)
Category A2, Partially controlled temperature, Pressurized to 15,000 feet
Operating temperature -15C TO +70C
Short time high operating temp +70C
Loss of cooling +40C
Ground Survival -55C to +85C
Altitude 15,000 feet
Decompression 55,000 feet
Overpressure -15,000 feet
Category F2, Non-controlled temperature, Non-pressurized, 55,000 feet maximum
Operating temperature -55C TO +70C
Short time high operating temp +70C
Loss of cooling +40C
Ground Survival -55C to +85C
Altitude 55,000 feet
Decompression N/A
Overpressure N/A
In-Flight Loss of Cooling (DO-160D Section 4.5.4)
Category W, 90 minutes minimum
The MARK III shall be able to operate with no forced cooling air at an ambient of +40° Celsius for a period of
90 minutes.
Temperature Variation (DO-160D Section 5.0)
Category B, Non-controlled temperature, Equipment mounted internal in aircraft
The maximum temperature variation rate is 5° Celsius per minute.
Humidity (DO-160D Section 6.0)
Category B, Severe Humidity environment
The unit shall withstand a 95% humidity, 10 day cycle.
Shock (DO-160D Section 7.0)
Category – B
Vibration (DO-160D Section 8.0)
Category – (UFF1)(SCLMY)
Explosion Proofness (DO-160D Section 9.0)
Category E
Non hermetically sealed equipment which meets the test requirements of environment I.