Note: Signal lines, not used in these steps, are used
for communications between the system and
the battery.
3. If the voltage is less than +8 V dc, recharge the
battery pack.
If the voltage is still less than +8 V dc after
recharging, replace the battery.
Terminal Signal / Voltage (V dc)
3 Reserved
4 Reserved
5 Thermal
6 Sense
7 Ground
System Board Check
The system board performs processing functions. Thus,
the system board can cause processor problems. To verify
the problem, do the following:
1. Boot from the diagnostics diskette and start the PQA
program (please refer to “Running the PQA Diagnos-
tics Program” on page 49).
2. Run the System Board test to verify the symptom.
This test verifies both the system board and the
processor board.
If the tests detect a system board problem, replace the
system board.
Note: Don't touch the keyboard and pointing device when
the system board test is running. This may cause
an unexpected error.
Memory Check
DIMM are available for increasing memory capacity.
DIMM DIMM Total Memory
32MB 0MB 32MB
0MB 32MB 32MB
32MB 32MB 64MB
64MB 0MB 64MB
0MB 64MB 64MB
64MB 32MB 96MB
32MB 64MB 96MB
64MB 64MB 128MB
128MB 0MB 128MB
0MB 128MB 128MB
128MB 32MB 160MB
ThinkPad i Series 1400 (Part I) 27