Error
Code
Message FRU/Action in Sequence
050 IDE Drive 0
Error
Ensure the hard disk
drive is set to [Auto] in
the "Basic System Set-
tings" menu of the
BIOS Utility.
Hard disk connection
board
Hard disk drive
System board
054 IDE Drive(s)
Disabled
Ensure the hard disk
drive is not set to
[None] in the "Basic
System Settings" menu
of the BIOS Utility.
Hard disk drive cable
Hard disk drive
056 IDE Drive 0
Auto Detection
Failed
Ensure the hard disk
drive is set to [Auto] in
the "Basic System Set-
tings" menu of the
BIOS Utility.
Hard disk connection
board
Hard disk drive
System board
070 Real Time
Clock Error
Reset time in the
"Basic System Set-
tings" menu of the
BIOS Utility.
Backup battery (RTC
battery)
System board
071 CMOS Battery
Bad
Enter BIOS Utility and
execute "Load Setup
Default Settings".
Backup battery (RTC
battery)
System board
072 CMOS
Checksum
Error
Enter BIOS Utility and
execute "Load Setup
Default Settings"; then
reboot the system.
Backup battery (RTC
battery)
System board
ThinkPad i Series 1400 (Part I) 37