IBM 2 Computer Hardware User Manual


 
Access_Control_Maintenance CCA Release 2.54
output_data_length
The output_data_length parameter is a pointer to an integer variable containing
the number of bytes of data in the output_data variable. The value must be a
multiple of four bytes.
On input, the output_data_length variable must be set to the total size of the
variable pointed to by the output_data parameter. On output, this variable will
contain the number of bytes of data returned by the verb in the output_data
variable.
output_data
The output_data parameter is a pointer to a string variable containing data
returned by the verb. Any integer value returned in the output_data field is in
big-endian format; the high-order byte of the value is in the lowest-numbered
address in storage. Authentication data structures are described in
“Access-Control Data Structures” on page B-28.
This field is used differently depending on the function being performed.
Rule-Array
Keyword
Contents of output_data Variable
LSTPROFS Contains a list of the profile IDs for all the user profiles stored
in the Coprocessor.
LSTROLES Contains a list of the role IDs for all the roles stored in the
Coprocessor.
2-26 IBM 4758 CCA Basic Services, Release 2.54, February 2005