IBM 6058 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
001-199-XXXSystem test failed, cause unknown
1. Go to the Undetermined problems section
2. Flash the system and re-test
3. Replace component under function test
001-250-XXXSystem ECC error
1. System board
001-254-XXX
001-255-XXX
001-256-XXX
001-257-XXXSystem DMA error
1. System board
001-260-XXX
001-264-XXXSystem IRQ error
1. System board
001-268-XXXSystem IRQ1 failure
1. Device on IRQ1
2. System board
001-269-XXXSystem IRQ2 failure
1. Device on IRQ2
2. System board
001-270-XXXSystem IRQ3 failure
1. Device on IRQ3
2. System board
001-271-XXXSystem IRQ4 failure
1. Device on IRQ4
2. System board
001-272-XXXSystem IRQ5 failure
1. Device on IRQ5
2. System board
001-273-XXXSystem IRQ6(diskette drive)
failure
1. Diskette Cable
2. Diskette drive
3. System board
001-274-XXXSystem IRQ7 failure
1. Device on IRQ7
2. System board
001-275-XXXSystem IRQ8 failure
1. Device on IRQ8
2. System board
001-276-XXXSystem IRQ9 failure
1. Device on IRQ9
2. System board
001-277-XXXSystem IRQ10 failure
1. Device on IRQ10
2. System board
001-278-XXXSystem IRQ11 failure
1. Device on IRQ11
2. System board
4 Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,
6649