Diagnostic Error Code FRU/Action
005-024-XXXVideo Addressing test failure
1. Video card, if installed
2. System board
005-025-XXXVideo Checksum Value error
1. Video card, if installed
2. System board
005-027-XXXVideo Configuration/Setup error
1. Run Setup
2. Video drivers update
3. Video card, if installed
4. System board
005-031-XXXVideo Device Cable failure
1. Video cable
2. Monitor
3. Video card, if installed
4. System board
005-032-XXXVideo Device Controller failure
1. Video card, if installed
2. System board
005-036-XXXVideo Register error
1. Video card, if installed
2. System board
005-038-XXXSystem BIOS extension failure
1. Video card, if installed
2. System board
005-040-XXXVideo IRQ failure
1. Video card, if installed
2. System board
005-195-XXXVideo Test aborted by user
1. Information
2. Re-start the test, if necessary
005-196-XXXVideo test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
005-197-XXXVideo test warning
1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
005-198-XXXVideo test aborted
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test
3. Go to the ″Undetermined problems″ section