IBM 6058 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
025-197-XXXIDE interface test warning
1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
025-198-XXXIDE interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problems section
025-199-XXXIDE interface test failed, cause
unknown
1. Go to the Undetermined problems section
2. Flash the system and re-test
3. Replace component under function test
030-000-XXXSCSI interface Test Passed
1. No action
030-00X-XXX
030-01X-XXXSCSI interface failure
1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-027-XXXSCSI interface
Configuration/Setup error
1. SCSI signal cable
2. Flash the system
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-03X-XXX
030-04X-XXXSCSI interface error
1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. installed System board
030-195-XXXSCSI interface Test aborted by
user
1. Information
2. Re-start the test, if necessary
030-196-XXXSCSI interface test halt, error
threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
Chapter 1. IBM PC Enhanced Diagnostics error codes 13