Diagnostic Error Code FRU/Action
086-198-XXXMouse Port interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test
3. Go to the ″Undetermined problems″ section
086-199-XXXMouse Port interface test failed,
cause unknown
1. Go to the ″Undetermined problems″ section
2. Flash the system and re-test
3. Replace component under function test
089-000-XXXMicroprocessor Test Passed
1. No action
089-XXX-XXXMicroprocessor failure
1. Microprocessor(s)
2. System board
089-195-XXXMicroprocessor Test aborted by
user
1. Information
2. Re-start the test, if necessary
089-196-XXXMicroprocessor test halt, error
threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
089-197-XXXMicroprocessor test warning
1. Make sure the component that is called out is
connected and/or enabled
2. Re-run test
3. Component that is called out in warning statement
4. Component under test
089-198-XXXMicroprocessor test aborted
1. Flash the system and re-test
2. Go to the ″Undetermined problems″ section
089-199-XXXMicroprocessor test failed, cause
unknown
1. If a component is called out, make sure it is
connected and/or enabled
2. Go to the ″Undetermined problems″ section
3. Flash the system and re-test
4. Replace component under function test
170-000-XXXVoltage Sensor(s) Test Passed
1. No action
170-0XX-XXXVoltage Sensor(s) failure
1. Flash system
2. System board
170-195-XXXVoltage Sensor(s) Test aborted by
user
1. Information
2. Re-start the test, if necessary
170-196-XXXVoltage Sensor(s) test halt, error
threshold exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
Chapter 1. IBM PC Enhanced Diagnostics error codes 17