Installing options 79
6. Slide the hot-swap hard disk drives back into place in the drive bays. If you need
to install additional hot-swap drives, do so now (see “Installing a hot-swap hard
disk drive” on page 81). You can connect a maximum of 10 hard disk drives to the
SCSI backplane.
Note: After you connect these hard disk drives to the SCSI backplane, the
backplane sets the SCSI IDs for the backplane and the hard disk drives.
See “Setting SCSI IDs” on page 97 for additional information.
7. Reinstall fan assembly 1 in the server.
8. Reconnect the shuttle.
a. Align the two shuttle pins with the holes on each side of the rear of the
chassis, and disengage the retaining levers from the notches on the chassis.
b. Move the retaining levers toward the front of the server, and secure the
retaining levers in the horizontal (locked) position.
9. If you disconnected the SCSI cable from the ServeRAID adapter in step 2 on page
73, reconnect the SCSI cable to the adapter.
10. If you have other options to install or remove, do so now; otherwise, go to
“Completing the installation” on page 91.
Installing internal drives
If you add different types of drives, the system can read multiple types of media and
store more data. Several types of drives are available, such as:
•Diskette
• Hard disk
•CD-ROM
•Tape
Internal drives are installed in bays. Your server comes with one 3.5-inch, 1.44 MB
diskette drive and one IDE CD-ROM drive.
Retaining lever
(locked position)
Retaining lever
(unlocked position)
Pin
Pin