IBM 6867 Personal Computer User Manual


 
Diagnostic Error Code FRU/Action
001-035-XXX
System Device Reset
condition detected
1. System board
001-036-XXX
System Register error
1. System board
001-038-XXX
System Extension failure
1. Adapter card
2. System board
001-039-XXX
System DMI data structure
error
1. Flash the system
2. System board
001-040-XXX
System IRQ failure
1. Power-off/on system
and re-test
2. System board
001-041-XXX
System DMA failure
1. Power-off/on system
and re-test
2. System board
001-195-XXX
System Test aborted by
user
1. Information
2. Re-start the test, if
need to
001-196-XXX
System test halt, error
threshold exceeded
1. Depress F3 to review
the log file.
2. Re-start the test to
reset the log file.
001-197-XXX
System test warning
1. Make sure
component that is
called out is enabled
and/or connected
2. Re-run test
3. Component that is
called out in warning
statement
4. Component under test
001-198-XXX
System test aborted
1. If a component is
called out, make sure
it is enabled and/or
connected
2. Flash the system and
re-test
3. Go to “Undetermined
problem” section.
001-199-XXX
System test failed, cause
unknown
1. Go to “Undetermined
problem” section.
2. Flash the system and
re-test
3. Replace component
under function test.
001-250-XXX
System ECC error
1. System board
001-254-XXX
001-255-XXX
001-256-XXX
001-257-XXX
System DMA error
1. System board
IBM PC Enhanced Diagnostics error codes 3