IBM 770 Laptop User Manual


 
Get System Resume Timer
Input Field
Major Function Number - 34
Minor Function Number - 2
Parameter 1 - Reserved
Parameter 2 - Reserved
Parameter 3 - Reserved
Parameter 4 - Reserved
Parameter 5 - Reserved
Output Field
Return Code - Error status
Auxiliary Return Code - Reserved
Parameter 1 - Reserved
Parameter 2 - Reserved
Parameter 3 - Reserved
Parameter 4 - TOD of resume timer (BCD format)
Bits 7- - Seconds (-59)
Bits 15-8 - Minutes (-59)
Bits 23-16 - Hours (-23)
Bits 31-24 - Reserved
Parameter 5 - Date of resume timer (BCD format)
Bits 7- - Day (1-31)
Bits 15-8 - Month (1-12)
Bits 23-16 - Year (-99)
Bits 3-24 - Reserved
Bit 31 - Resume date validation
=  - Valid (specified day)
= 1 - Invalid (every day)
SMAPI BIOS B-49