IBM NH2025-10 Switch User Manual


 
Configuring, Modifying, and Monitoring the Unit
51
VLAN Management
The processor that manages the product (SNMP responses and traps, remote telnet connections)
does not belong to a VLAN that you have declared previously, so to get access to the processor
through the network it is recommended to make the processor a part of a chosen VLAN with the
following set of commands.
Viewing the Management Tag
get-mgmt-vlan-tag
By default the Management processor belongs to (CPU) VLAN tag 1.
get-mgmt-vlan-tag {run|nvram}
Example
SYS_console>get-mgmt-vlan-tag run
Management VLAN tag: 1
SYS_console>
Modifying the Management Tag
add-mgmt-to-vlan
The add-mgmt-to-vlan command adds management (CPU) to an existing VLAN.
add-mgmt-to-vlan <database> <VTAG>
[arg #0] database type - either {run|nvram}
[arg #1] VLAN Tag { 2 .. 4095 }
Example
SYS_console>add-mgmt-to-vlan run 10
Set Management VLAN TAG 10 –OK
SYS_console>
Deleting the Management from a VLAN
del-mgmt-from-vlan
The del-mgmt-from-vlan command returns the management VLAN tag to default value (1).
Example
SYS_console>del-mgmt-from-vlan run
Del Management VLAN – OK
SYS_console>