IMC Networks iMcV-T1/E1/J1 Network Router User Manual


 
Testing
To test a media converter by itself, first make sure you have an appropriate fiber
patch cable, then perform the following steps:
1.
Connect the media converter to the T1/E1 device with a standard UTP cable. If
the
NO LNK
LED for the copper port remains on, you are not receiving a valid
signal. Push the crossover push button on the front of the unit. Verify that the
NO LNK
LED for the copper port is off.
2.
Loop a single strand of fiber from the transmit port to the receive port of the
media converter. Verify that the
NO LNK
LED for the fiber port is off.
Or
For single-strand fiber products, connect a single fiber cable from the Local
iMcV-T1/E1/J1 to the remote iMcV-T1/E1/J1. Verify that the
NO LNK
LED for
the fiber port is off.
Loopback Testing
The iMcV-T1/E1/J1 includes the following loopback locations:
Local
Remote
Analog.
Local Loopback
The Local loopback location on the module
loops the fiber-receive port to the fiber-transmit
port.
Remote Loopback
The Remote loopback location on the module
loops the fiber-transmit port to the fiber-
receive port.
Analog Loopback
The Analog loopback location on the module
loops the copper-transmit port to the copper-
receive port.
15