InFocus IN20 Projector User Manual


 
36
WARNING:
Be extremely careful when removing the lamp housing. In the
unlikely event that the bulb ruptures, small glass fragments may be
generated. The lamp housing is designed to contain these frag
-
ments, but use caution when removing the lamp housing. Before
replacing the lamp, clean the lamp compartment and dispose of
cleaning materials. Wash hands after lamp replacement. This prod
-
uct has a lamp which contains a very small amount of mercury. Dis-
pose of it as required by local, state or federal ordinances and
regulations. For more information see www.eiae.org.
5 Detach the lamp connector from the projector by depressing the locking
tab on the connector and lightly pulling it free.
6 Loosen the captive screw that attaches the lamp housing to the projector.
Carefully remove the lamp housing. Dispose of the lamp in an environ-
mentally proper manner.
7 Install the new lamp housing and tighten the screw.
8 Re-attach the lamp connector to the projector. The locking tab should
engage when the connector is fully plugged in.
9 Replace the lamp door by sliding it into place. Be sure the lamp connec-
tor wires are not in the way.
10 Plug in the power cord and press the Power button to turn the projector
back on.
11 To reset the lamp hour timer, navigate to the Settings>Service menu
and select Reset Lamp Hours. See
page 33 for details.
squeeze lamp connector
loosen screw
Service menu