ECB-862/862L
ECB-862/862L User’s Manual 95
Invalid EISA Configuration
Please Run EISA Configuration Utility
The non-volatile memory containing EISA configuration information was programmed
incorrectly or has become corrupt. Re-run EISA configuration utility to correctly program
the memory.
NOTE: When this error appears, the system will boot in ISA mode, which allows you to run the EISA
Configuration Utility.
Keyboard Error Or No Keyboard Present
Cannot initialize the keyboard. Make sure the keyboard is attached correctly and no keys
are being pressed during the boot.
If you are purposely configuring the system without a keyboard, set the error halt condition
in Setup to HALT ON ALL, BUT KEYBOARD. This will cause the BIOS to ignore the
missing keyboard and continue the boot.
Memory Address Error At...
Indicates a memory address error at a specific location. You can use this location along
with the memory map for your system to find and replace the bad memory chips.
Memory Parity Error At...
Indicates a memory parity error at a specific location. You can use this location along with
the memory map for your system to find and replace the bad memory chips.
Memory Size Has Changed Since Last Boot
Memory has been added or removed since the last boot. In EISA mode use Configuration
Utility to reconfigure the memory configuration. In ISA mode enter Setup and enter the
new memory size in the memory fields.
Memory Verify Error At...
Indicates an error verifying a value already written to memory. Use the location along with
your system's memory map to locate the bad chip.
Offending Address Not Found
This message is used in conjunction with the I/O CHANNEL CHECK and RAM PARITY
ERROR messages when the segment that has caused the problem cannot be isolated.
Offending Segment
This message is used in conjunction with the I/O CHANNEL CHECK and RAM PARITY
ERROR messages when the segment that has caused the problem has been isolated.