Intel SROMBSASMR (AXXROMBSASMR) Personal Computer User Manual


 
Appendix A: Event Messages and Error Codes Intel® Integrated RAID Module SROMBSASMR (AXXROMBSASMR) Technical Product Specification
Intel order number E59029-003
26
Appendix A: Event Messages and Error Codes
This appendix lists the Intel
®
RAID Web Console 2 events that may appear in the event log.
The Intel
®
RAID Web Console 2 utility monitors the activity and performance of all controllers in
the server and any devices attached to them. When an “event” such as the completion of a
consistency check or the removal of a physical drive occurs, an event message is displayed in
the log, which appears at the bottom of the Intel
®
RAID Web Console 2 screen. The messages
are also logged in the Windows Application Log (Event Viewer). Error event levels are:
Progress: This is a progress posting event. Progress events are not saved in NVRAM.
Information: Informational message. No user action is necessary.
Warning: A component may be close to a failure point.
Critical: A component has failed, but the system has not lost data.
Fatal: A component has failed, and data loss has occurred or will occur.
Dead: A catastrophic error has occurred and the controller has failed. This is seen only
after the controller has been restarted.
The following table lists the Intel
®
RAID Web Console 2 event messages.
Table 15. Event Messages
Number Type Description
0 Information Firmware initialization started (PCI ID %04x/%04x/%04x/%04x)
1 Information Firmware version %s
2 Fatal Unable to recover cache data from TBBU
3 Information Cache data recovered from TBBU successfully
4 Information Configuration cleared
5 Warning Cluster down; communication with peer lost
6 Information %s ownership changed from %02x to %02x
7 Information Alarm disabled by user
8 Information Alarm enabled by user
9 Information Background initialization rate changed to %d%%
10 Fatal Controller cache discarded due to memory/battery problems
11 Fatal Unable to recover cache data due to configuration mismatch
12 Information Cache data recovered successfully
13 Fatal Controller cache discarded due to firmware version incompatibility
14 Information Consistency Check rate changed to %d%%
15 Dead Fatal firmware error: %s
16 Information Factory defaults restored A249
17 Warning Flash downloaded image corrupt
18 Critical Flash erase error
19 Critical Flash timeout during erase
20 Critical Flash error
21 Information Flashing image: %s
Revision 1.2