Intel SROMBSASMR (AXXROMBSASMR) Personal Computer User Manual


 
Intel® Integrated RAID Module SROMBSASMR (AXXROMBSASMR) Technical Product Specification Appendix A: Event Messages and Error Codes
Number Type Description
198 Information Consistency Check Aborted Due to Ownership Loss on %s
199 Information Background Initialization (BGI) Aborted Due to Ownership Loss on %s
200 Critical Battery/charger problems detected; SOH Bad
201 Warning Single-bit ECC error: ECAR=%x
202 Critical Single-bit ECC error: ECAR=%x
203 Critical Single-bit ECC error: ECAR=%x
204 Warning Enclosure %s Power supply %d switched off
205 Information Enclosure %s Power supply %d switched on
206 Warning Enclosure %s Power supply %d cable removed
207 Information Enclosure %s Power supply %d cable inserted
208 Information Enclosure %s Fan %d returned to normal
209 OBSOLETE
210 Information BBU Retention test passed
211 Critical BBU Retention test failed!
212 OBSOLETE
213 Information NVRAM Retention test passed
214 Critical NVRAM Retention test failed!
215 Information %s test completed %d passes successfully
216 Critical %s test FAILED on %d pass. Fail data: errorOffset=%x goodData=%x badData=%x
217 Information Self-check diagnostics completed
218 Information Foreign Configuration Detected
219 Information Foreign Configuration Imported
220 Information Foreign Configuration Cleared
221 Warning NVRAM is corrupt; reinitializing
222 Warning NVRAM mismatch occurred
223 Warning SAS wide port %d lost link on PHY %d
224 Information SAS wide port %d restored link on PHY %d
225 Warning SAS port %d, PHY %d has exceeded the allowed error rate
226 Information Bad block reassigned on %s at %lx to %lx
227 Information Controller Hot Plug detected
228 Warning Enclosure %s temperature sensor %d differential detected
229 Information Disk test cannot start. No qualifying disks found
230 Information Time duration provided by host is not sufficient for self check
231 Information Marked Missing for %s on array %d row %d
232 Information Replaced Missing as %s on array %d row %d
233 Information Enclosure %s temperature sensor %d returned to normal
234 Information Enclosure %s Firmware download in progress
235 Warning Enclosure %s Firmware download failed
236 Warning %s is not a certified drive
237 Information Dirty cache data discarded by user
238 Warning PDs missing from configuration at boot
239 Warning VDs missing drives and will go offline at boot: %s
240 Warning VDs missing at boot: %s
241 Warning Previous configuration completely missing at boot
Revision 1.2
Intel order number E59029-003
31