Parameters used for the data format
The following 2 types of parameters are used for command and response data:
(1) ON/OFF (2) Special Parameter
Each parameter is as follows:
(1) ON/OFF
Shows the status (ON or OFF) of the unit, such as POWER and HIDE.
(2) Special parameters
Operation mode parameters
DHCP client parameters
IP address parameters
Display the IP address using the dot (“.” (2HE)) delimiter.
Example: “192.168.0.10”
External control command table
NOTE:
After configuring the ADHCP ClientB and AIP AddressB, execute ANetwork RestartB.
Character Hex Meaning
030OFF
131 ON
Character Hex Meaning
0000 30 30 30 30 Standby state
0001 30 30 30 31 Power ON state
0002 30 30 30 32 Cooling state
0003 30 30 30 33 Emergency cooling state
0004 30 30 30 34 Emergency state
Character Hex Meaning
0 30 DHCP
1 31 Static IP
Function Command
Setting Asking Data Type
Power On ELSE Power On ELSE ON/OFF Special Parameter
Power U0F
3(OFF) 3(ON)
--3 -
Hide U00
3 - 3 - 3 -
Operation Mode UA0
--33-
Standby...
DHCP Client UD2
3333-
DHCP...
IP Address UD3
3333-
192.168. ...
Network Restart UDC
3333-
[0] Fixed