How to Use the External Control
7 About the External Control
The Monitor has the MAKE/TRIGGER terminal, which allows you to control the monitor by the MAKE (make
contact) or TRIG. (trigger) system selected in the function setting.
MAKE (make contact) system: Controls the function by short-circuiting the corresponding pin terminal to the
GND pin terminal, or disconnecting (opening) it.
TRIG. (trigger) system: Controls the function by inputting the pulse signal instantaneously to the
corresponding pin terminal.
* Select “MAKE” or “TRIG.” from “REMOTE SYSTEM” in SET-UP MENU.
“REMOTE SYSTEM” on page 14
NOTES:
The external control has priority over operations using front panel buttons or menu functions of the monitor.
When using the make contact system, you cannot use the functions which are applied to the MAKE/TRIGGER terminal
operating the front panel buttons or the menu of the monitor. (When using the trigger system you can also use those
functions operating the monitor directly.)
7 How to Use the MAKE/TRIGGER Terminal
7 Function of the MAKE/TRIGGER terminal
The following are the configurations and the functions
of the pin terminals of the RJ-45 connector. You can
change the functions applied to the 1st to 6th pin
terminals by setting “REMOTE SYSTEM” of SET-UP
MENU.
Caution:
This is a female
connecter.
7 To change the functions applied to the pin
terminals
1. Display SET-UP MENU, then move the MENU
control to / to select “REMOTE SYSTEM,” then
move it to .
2. Move the MENU control to / to select
“CONTROL FORM,” then move it to / to select
“SET.”
3. Move the MENU control to / to select the
number of the pin terminal (PORT F1 – PORT F6)
you want to set, then move it to / to select the
function.
NOTE:
•You cannot apply two or more functions to one terminal.
NO.
1
2
3
4
5
6
7
8
INP. A
INP. C
MARKER
ASPECT
TALLY
L. METER
Functions to be controlled
Changes the input to INPUT A
Changes the input to INPUT C
Tur ns on/off MARKER
Changes ASPECT
Controls the tally lamp
Tur ns on/off AUDIO LEVEL
METER
External control
GND