Kingston Technology KNE24TP/RS Switch User Manual


 
16 Appendix B Cabling Guidelines
Kingston Technology Company KNE24TP/RS User’s Guide - Rev. A01
Appendix B Cabling Guidelines
Cable Types
When connecting network cables, the following table shows appropriate
networking guidelines associated with each cable type.
Ethernet Standard: 10BASE5 10BASE2 10BASE-T
Cable Type:
RG-11 RG-58/U UTP CAT
3, 4 or 5
Max. Segment
Length:
500M
(1640ft)
185M
(600ft)
100M
(328ft)
Max. Number of
Nodes per Segment:
100
30
1024
Connector:
15-pin D-Sub BNC RJ-45
Network Topology:
Linear Bus Linear Bus Star
Table B-1 Network Cable Guidelines
UTP Cable Wiring
10BASE-T unshielded twisted-pair cables can be wired as "Straight-Thru" or,
in some cases, "Crossover" depending on the application. For workstations
connected to a hub, use "Straight-Thru' wiring illustrated below in Table B-2.
In some instances (e.g. cascading from one hub to another), you may use
"Crossover" wiring illustrated below in Table B-3.
"Straight-Thru" Crossover”
Cable Wiring Cable Wiring
1 (TRX +)
2 (TRX -)
3 (RCV +)
6 (RCV -)
4, 5, 7, 8
1 (TRX +)
2 (TRX -)
3 (RCV +)
6 (RCV -)
Not Used
Pin Number Pin Number
1 (TRX +)
2 (TRX -)
3 (RCV +)
6 (RCV -)
4, 5, 7, 8
3 (RCV +)
6 (RCV -)
1 (TRX +)
2 (TRX -)
Not Used
Pin Number Pin Number
Table B-2. Straight-Thru Wiring Table B-3. Crossover Wiring