Wiring the TP Line In/Line Out Connectors
28
8 Wiring the TP Line In/Line Out Connectors
STP cabling
1
with a length of 15.2m (50ft) in length is available for use with
the Kramer A/V SummitView systems for connecting to the SV-301xl/302
Wall Plates. When required, longer STP cabling can be used when purchased
for standalone wall plates but we recommend a maximum transmission range
of 30m (100ft). Exceeding the recommended distance may result in reduced
image quality.
Connecting the SV-306/307 requires BC-DGKat524 or BC-DGKat-623
cable (see
Section 8.3
This section describes how to connect the rear panel for the:
).
US wall plate versions (see
Section 8.1
European wall plate versions (see
)
Section 8.2
)
8.1 Wiring the Twisted Pair RJ-45 Terminals (U.S.)
The U.S. versions of the wall plates are equipped with RJ-45 terminals.
Table 14 defines the TP pinout, using a straight pin to pin cable with RJ-45
connectors. When using STP cable, connect/solder the cable shield to the RJ-45
connector shield.
1 Plenum-rated for the SummitView™ US version; non-plenum for the SummitView™ Europe