KTI Networks KS-2260 Switch User Manual


 
-33-
The following 100FX modules are supported by F23 and F24 slots:
Part Number Connector Cable Distance
2260-FMT Duplex ST MMF* 2 km
2260-FMC Duplex SC MMF 2 km
2260-FJM MT-RJ MMF 2 km
2260-FVM VF-45 MMF 2 km
2260-FSA2 Duplex SC SMF* 20 km
Note: * MMF - Multimode Fiber cable 50/125, 62.5/125 mm
* SMF - Single Mode Fiber cable 8.7/125, 9/125, 10/125 mm
Specifications
IEEE 802.3u 100BASE-FX compliant, Fixed 100Mbps, Fixed Full duplex
Optical Specifications
Part Number Wavelength Output Power Input Optical Power
2260-FMT 1310nm -19 ~ -14dBm -31dBm min. -14dBm max.
2260-FMC 1310nm -19 ~ -14dBm -31dBm min. -14dBm max.
2260-FJM 1310nm -20 ~ -14dBm -31dBm min. -14dBm max.
2260-FVM 1310nm -20.5 ~ -15dBm -33dBm typ. sensitivity
2260-FSA2 1310nm -18 ~ -7dBm -32dBm max. sensitivity
Installation steps:
1. Turn the power to the switch off.
2. Set JP1.
3. Insert the 100FX modules and screw the modules securely.
4. Turn the power to the switch on.