Lantronix EDS-MD16 Server User Manual


 
6: Line and Tunnel Settings
EDS-MD User Guide 42
To Configure Tunnel Connect Mode Settings
Using Web Manager
To configure the Connect Mode for a specific tunnel, click Tunnel in the menu and select
Tunnel 1 -> Connect Mode.
Using the CLI
To enter the Tunnel 1 Connect Mode command level: enable -> tunnel 1 -> connect
Using XML
Include in your file: <configgroup name="tunnel connect" instance="1">
Disconnect Mode
Specifies the optional conditions for disconnecting any Accept Mode or Connect Mode connection
that may be established. If any of these conditions are selected but do not occur and the network
disconnects to the device, a Connect Mode connection will attempt to reconnect. However, if none
of these conditions are selected, a closure from the network is taken as a disconnect.
Table 6-7 Tunnel Disconnect Mode Settings
Block Serial Set whether Block Serial is enabled for debugging purposes. Choices are:
Enabled = If Enabled, incoming characters from the Serial Line will not be
forwarded to the network. Instead, they will be buffered and will
eventually flow off the Serial Line if hardware or software flow control is
configured.
Disabled = this is the default setting; incoming characters from the Serial
Line are sent on into the network. Any buffered characters are sent first.
Block Network Set whether Block Network is enabled for debugging purposes. Choices are:
Enabled = If Enabled, incoming characters from the network will not be
forwarded to the Serial Line. Instead, they will be buffered and will
eventually flow off the network side.
Disabled = this is the default setting; incoming characters from the
network are sent on into the Serial Line. Any buffered characters are sent
first.
Email on Connect Select an email profile number to which an email notification will be sent
upon the establishment of an accept mode tunnel.
Email on Disconnect Select an email profile number to which an email notification will be sent
upon the disconnection of an accept mode tunnel.
Tunnel Disconnect
Mode Settings
Description
Stop Character Enter the Stop Character which when received on the Serial Line, disconnects
the tunnel. The Stop Character may be designated as a single printable
character or as a control character. Control characters may be input in any of
the following forms: <control>J or 0xA(hexadercimal) or \10 (decimal).
Disable the Stop Character by blanking the field to set it to <None>.
Tunnel Connect Mode
Settings (continued)
Description