Lathem PC400TX Time Clock User Manual


 
24 - PC400 Terminal Installation & User’s Guide
A PPENDIX D
Installing a TCP/IP 10Base T Module in the PC400
¾ Remove the PayClock 400 Terminal from the Back Box
1. Unlock and remove the terminal from the back box. Place the terminal on a
comfortable workspace.
2. Using a Philips screwdriver, remove and save the 4 Philips head screws at each
corner of the internal cover plate of the PayClock terminal; see Figure 9
3. Remove and discard the modem cover plate, then remove the internal cover
plate; see Figure 11.
¾ Install the 10Base T Module
4. Carefully plug the 10Base T module into the empty socket at the U26 location
on the circuit board; see Figure 11.
5. Replace the internal cover plate and install the 4 Philips head screws. Do not
install the modem cover plate.
6. Align the tabs on the back box with slots at the top of the internal cover plate.
Plug in the power cable and Ethernet cable. Then lower the terminal into place.
7. Turn the key to lock the terminal onto the back box.
¾ Setup the Terminal
8. Enter the Terminal Setup Mode by pressing 729255 on the keypad. Set the date,
day of week, time, baud rate (9600) and terminal ID.
CAUTION: Follow these 2 steps before installing the 10Base T module installation
1. Disconnect the power from the PC400.
2. Discharge any static in your body by touching a large metal object
NOTE: This 10Base T upgrade requires firmware version 3.05 or later and circuit
board revision K or later.