Lenovo 6397 Computer Hardware User Manual


 
Diagnostic Error Code FRU/Action
000-026-XXX FLASH data error 1. Flash the system. See “Updating (ashing) BIOS
from a CD-ROM or diskette” on page 139
2. System board
000-027-XXX BIOS Conguration/Setup error 1. Run Setup
2. Flash the system. See “Updating (ashing) BIOS from
a CD-ROM or diskette” on page 139
3. System board
000-034-XXX BIOS Buffer Allocation failure
1. Reboot the system
2. Flash the system. See “Updating (ashing) BIOS from
a CD-ROM or diskette” on page 139
3. Run memory test
4. System board
000-035-XXX BIOS Reset Condition detected 1. Flash the system. See “Updating (ashing) BIOS
from a CD-ROM or diskette” on page 139
2. System board
000-036-XXX BIOS Register error 1. Flash the system. See “Updating (ashing) BIOS
from a CD-ROM or diskette” on page 139
2. System board
000-038-XXX BIOS Extension failure 1. Flash the system. See “Updating (ashing) BIOS
from a CD-ROM or diskette” on page 139
2. Adapter card
3. System board
000-039-XXX BIOS DMI data error 1. Flash the system. See “Updating (ashing) BIOS
from a CD-ROM or diskette” on page 139
2. System board
000-195-XXX BIOS Test aborted by user
Information only Re-start the test, if necessary
000-196-XXX BIOS test halt, error threshold exceeded
1. Press F3 to review the log le
2. Re-start the test to reset the log le
000-197-XXX BIOS test warning
1. Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
000-198-XXX BIOS test aborted
1. Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 39
2. Flash the system and retest. See “Updating (ashing)
BIOS from a CD-ROM or diskette” on page 139
3. Go to “Undetermined problems” on page 62
000-199-XXX BIOS test failed, cause unknown 1. Go to “Undetermined problems” on page 62
2. Flash the system and re-test
3. Replace component under function test
44 Hardware Maintenance Manual