Liebert VM12000 Power Supply User Manual


 
5
Heat Rejection
at Full Load
BTU / HR
2170
2411
3616
4520
5062
7593
Weight
Including
Battery (lbs.)
270
270
560
560
560
780
Mechanical Data
Dimensions
in Inches
WxDxH
9x31x29
9x31x29
18x27x29
9x31x29
9x31x29
27x27x29
UPS Output
Circuit Breaker
(Amps)
30 A
30 A
100 A
100 A
100 A
125 A
Full Load
Currnet†Amps
23 A
22 A
21 A
20 A
19 A
25 A
25 A
25 A
25 A
25 A
40 A
39 A
36 A
35 A
33 A
50 A
48 A
46 A
44 A
42 A
60 A
58 A
55 A
52 A
50 A
90 A
87 A
82 A
78 A
75 A
AC Output
Voltage VAC
3-Wire +Ground
200/100
208/120
220/110, 220/127, 220 L-N
230/115
240.120, 240 L-N
200/100
208/120
220/110, 220/127, 220 L-N
230/115
240.120, 240 L-N
200/100
208/120
220/110, 220/127, 220 L-N
230/115
240.120, 240 L-N
200/100
208/120
220/110, 220/127, 220 L-N
230/115
240.120, 240 L-N
200/100
208/120
220/110, 220/127, 220 L-N
230/115
240.120, 240 L-N
200/100
208/120
220/110, 220/127, 220 L-N
230/115
240.120, 240 L-N
Battery
Internal Battery
Time Full / Half
Load¶ Minutes
12 /29
11 / 25
17 / 35
11 / 28
10 / 24
10 / 27
Recommende
d External
Overcurrent
Protection*
(Amps)
30 A
30 A
60 A*
60 A*
60 A*
50 A*
50 A*
70 A*
70 A*
70 A*
60 A*
60 A*
80 A
80 A
80 A
70 A
70 A
125 A
120 A
120 A
110 A
110 A
Full Load
Current †
Amps
22 A
21 A
20 A
19 A
18 A
24 A
24 A
22 A
21 A
20 A
36 A
35 A
33 A
31 A
30 A
45 A
43 A
41 A
39 A
38 A
50 A
49 A
46 A
44 A
42 A
76 A
72 A
69 A
66 A
63 A
AC Input
Voltage VAC
3-Wire + Ground §
200/100
208/120
220/110, 220/127, 220 L-N
230/115
240/120, 240 L-N
200/100
208/120
220/110, 220/127, 220 L-N
230/115
240/120, 240 L-N
200/100
208/120, 208/120 3 Ph. §
220/110, 220/127, 220 L-N
230/115
240/120, 240 L-N
200/100
208/120, 208/120 3 Ph. §
220/110, 220/127, 220 L-N
230/115
240/120, 240 L-N
200/100
208/120, 208/120 3 Ph. §
220/110, 220/127, 220 L-N
230/115
240/120, 240 L-N
200/100
208/120, 208/120 3 Ph. §
220/110, 220/127, 220 L-N
230/115
240/120, 240 L-N
Maximunm
Upgrade
Rating (kVA)
5.0
5.2
5.5
5.8
6.0
N/A
12.0
12.0
N/A
N/A
Power Rating
Power Rating
kVA/ kW
4.5 / 3.6
5.0 / 4.0
5.2 / 4.0
5.5 / 4.0
5.8 / 4.0
6.0 / 4.0
8.0 / 6.0
10.0 / 7.5
12.0 / 8.4
18.0 / 12.6
* For planned future upgrade, initially size wiring and overcurrent protection for future upgraded size.
¶ Extended run times available with optional external matching battery cabinets.
§ 8-18 kVA units accept optional 208V 3-phase 4-wire plus ground input. Full load current shown is based on UPS operation in bypass mode. In bypass mode, the UPS draws single phase current from the source, regardless of single or 3-phase input configuration.
† Full load current is the maximum amperage that each phase conductor can carry (L1-L2, L1-N, or L2-N), while not exceeding the total watt or kVA rating of the system.
Liebert UPStation S™ SITE PLANNING DATA