Marantz PD5020D Computer Monitor User Manual


 
51
45. COLOR SYSTEM Select
Function
The external control equipment sets the COLOR SYSTEM of the plasma monitor.
Transmission Data
DFH 80H 60H 5CH 01H
DATA00
CKS
DATA00: 01H: 3.58NTSC
02H: 4.43NTSC
03H: PAL
04H: SECAM
0AH: AUTO1
0BH: PAL60
0CH: AUTO2
0DH: PAL- M
0EH: PAL- N
ACK
7FH 60H 80H 5CH 01H
DATA00
CKS
DATA00: 01H: 3.58NTSC
02H: 4.43NTSC
03H: PAL
04H: SECAM
0AH: AUTO1
0BH: PAL60
0CH: AUTO2
0DH: PAL- M
0EH: PAL- N
46. Multi Screen Select
Function
The external control equipment selects single screen mode or multi screen
mode of the display.
Transmission Data
DFH 80H 60H 07H 01H DATA00 CKS
DATA00: Multi Screen
00H: Single screen
01H: Side by Side1 (Same size screen)
02H: Side by Side2 (Left screen smaller)
03H: Picture in Picture sub screen L1
04H: Picture in Picture sub screen R1
05H: Side by Side3 (Left screen bigger)
06H: Picture in Picture sub screen L2
07H: Picture in Picture sub screen R2
08H: Picture in Picture sub screen L3
09H: Picture in Picture sub screen R3
0AH: Picture in Picture sub screen L4
0BH: Picture in Picture sub screen R4
10H: SWAP (The screen of the right and the left interchanges)
Side by Side
20H: Active Left
21H: Active Right
Picture in Picture
30H: Active Main
31H: Active Sub
ACK
The display returns the following ACK.
7FH 60H 80H 07H 01H DATA00 CKS
DATA00: Multi Screen
00H: Single screen
01H: Side by Side1 (Same size screen)
02H: Side by Side2 (Left screen smaller)
03H: Picture in Picture sub screen L1
04H: Picture in Picture sub screen R1
05H: Side by Side3 (Left screen bigger)
06H: Picture in Picture sub screen L2
07H: Picture in Picture sub screen R2
08H: Picture in Picture sub screen L3
09H: Picture in Picture sub screen R3
0AH: Picture in Picture sub screen L4
0BH: Picture in Picture sub screen R4
10H: SWAP (The screen of the right and the left interchanges)
Side by Side
20H: Active Left
21H: Active Right
Picture in Picture
30H: Active Main
31H: Active Sub
When other commands (except POWER OFF) are sent while the screens are
switching with this command, the other command will be returned as “Not
Available” until screen switching is finished.