Maretron FPM100 Computer Monitor User Manual


 
FPM100 User’s Manual
Page 16 Revision 1.3
Electrical
Parameter Value Comment
Operating Voltage 9 to 32 Volts DC Voltage
Power Consumption 400mA Maximum Current Drain
Load Equivalence Number (LEN) 8 NMEA 2000
®
Spec. (1LEN = 50mA)
Reverse Battery Protection Yes Indefinitely
Load Dump Protection Yes Energy Rated per SAE J1113
Mechanical
Parameter Value Comment
Size 3.50” x 4.20” x 2.03”
(88.9mm x 106.7mm x 51.6mm)
Including Flanges for Mounting
Weight 13 oz. (368.5 g)
Environmental
Parameter Value
IEC 60945 Classification Exposed
Degree of Protection IP64
Operating Temperature -25°C to 55°C
Storage Temperature -40°C to 70°C
Relative Humidity 93%RH @40° per IEC60945-8.2
Vibration 2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s
2
per IEC 60945-8.7
Solar Radiation Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10
Corrosion (Salt Mist) 4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12
Electromagnetic Emission Conducted and Radiated Emission per IEC 60945-9
Electromagnetic Immunity Conducted, Radiated, Supply, and ESD per IEC 60945-10
Safety Precautions Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12
7 Technical Support
If you require technical support for Maretron products, you can reach us in any of the following
ways:
Telephone: 1-866-550-9100
Fax: 1-602-861-1777
E-mail: support@maretron.com
World Wide Web: http://www.maretron.com
Mail: Maretron, LLP
Attn: Technical Support
9014 N. 23
rd
Ave Suite 10
Phoenix, AZ 85021 USA