20
Specifications
General
Rated Power Supply: 100 to 240 V AC, 50/60 Hz
Rated Input: 0.75 - 0.4 A (100-240 V)
Operating Temperature: 41 °F-104 °F (5 °C to 40 °C)
Relative Humidity: Max. 80 (%)
Altitude: Max. 2000 (m)
Dimensions: 424 (Width) x 361 (Depth) x 49 (Height) (mm)
Weight: 6.3 kg (with 2 HDD mounted)
Control terminals
CONT IN Input terminal linked with the power supply of the recorder
CONT OUT Output terminal linked with the power supply of the recorder
(CONT OUT is the through output of CONT IN.)
GND (Ground) For grounding
TEMP ALM Output terminal for detecting abnormal temperature (open collector output)
Active: “Low” level voltage output, Max. current 7 mA DC.
Non active: Open, Max. voltage 24 V DC.
FAN ALM Output terminal for detecting fan error (open collector output)
Active: “Low” level voltage output, Max. current 7 mA DC.
Non active: Open, Max. voltage 24 V DC.
HDD ALM Output terminal for detecting HDD error (open collector output)
Active: “Low” level voltage output, Max. current 7 mA DC.
Non active: Open, Max. voltage 24 V DC.
CONT IN Reserved.
CONT OUT Reserved.
EXTERNAL CONTROL:
When set to ON: Power is supplied to the HDD when 12V is applied to the input terminal linked with the power supply.
When set to OFF: Power is always supplied to the HDD.
Serial bus terminal
Serial bus terminal (2 terminals) (Only DX-ZD6UE is connectable.)
Accessories: USB2.0 cable 1
Control cable 1
Screws 8
User’s manual (this manual) 1
Power cord 3
Control input/output terminals and circuits
<Interface circuit inside the unit>
Output terminal
GND terminal
TEMP ALM terminal
FAN ALM terminal
HDD ALM terminal
• Output Circuit
Design and specifications are subject to change without notice.