Mitsubishi Electronics SD206U Projector User Manual


 
EN-26
Indicators
This projector has two indicators, each of which shows the operation condition of the projector.
The following offer solutions to possible problems. If these problem persist, turn the projector off and consult your dealer.
Normal condition
Abnormal condition
POWER STATUS CONDITION NOTE
Stand-by
Power up process (About 4 seconds)
The power is on. (Normal condition)
Lamp cooling down. (About 90 seconds)
Lamp lit up (About 60 seconds)
STATUS indicator POWER indicator
Steady red
Off
Blinking red
Off
Steady green
Steady green
Steady green
Blinking green
POWER STATUS CONDITION POSSIBLE SOLUTION
Lamp failure Replace the lamp and reset the lamp hour.
Color wheel failure Contact your dealer.
Fan failure
Check if the fan is clogged with dust or dirt and
clean it.
If the above solution is not effective, contact your
dealer.
Abnormal temperature
Clean the ventilation grilles.
Relocate the projector to a cooler place.
For the directly shut down, it will check the
temperature first, if it's too high, it will start
cooling for 90 seconds.
If it's abnormal shut down in the previous time,
while the temperature is too high, it will start the
cooling process after 90 seconds when the
temperature is still too high.
95% Lamp life exceed Replace the lamp and reset the lamp hour.
Lamp life end Replace the lamp and reset the lamp hour.
Lamp cover open Put back the lamp cover.
Off
Blinking green about
30 seconds after
power on.
Steady green
Steady amber
about 5 seconds after
power on.
Blinking green
Steady green about
20 seconds after
power on.
Steady green
Steady red about 10
seconds after power
on.
Steady green
Blinking red
Off
Steady red about 5
seconds after power
on.
N/A
N/A