Mocomtech IP-Enabled M&C Network Hardware User Manual


 
CiM-25/600L IP Enabled M&C Rev. 1
SNMP Interface CD/CIM25600L.IOM
93
A.6.60 DROPANDINSERT
Name
dropAndInsert
OID
1.3.6.1.4.1.6247.21.1.5.16
Full path
iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).comtech(6247)
.cdm600l(21).cdm600lObjects(1).interfaceParameters(5).dropAndInser
t(16)
Module
CDM600L
Parent
interfaceParameters
Prev sibling
rxAudioVolume
Next sibling
txTerrestrialAlarmMask
Type
OBJECT-TYPE
Numerical syntax
SNMP_SYNTAX_OCTETS
Base syntax
OCTET STRING
Composed syntax
OCTET STRING
Status
current
Max-access
read-write
Size list
1
51
Description
Drop & Insert. (DNI?, DNI=) 51 Bytes.
25 bytes of Drop information - 24 bytes defining Timeslot locations,
followed by Drop type (0 = T1-D4, 1 = T1-ESF, 2 = E1-CCS, 3 =
E1-CAS) as DTY
25 bytes of Insert information - 24 bytes defining Timeslot
locations, followed by Insert type (0 = T1-D4, 1 = T1-ESF, 2 =
E1-CCS, 3 = E1-CAS) as ITY
Timeslot definition
0 = Unused
1-9 for timeslots 1-9 A=10, B=11, C=12, D=13...V=31.
Last byte = Drop and Insert Internal Loop (0 = OFF, 1 = ON)
If data rate equals 1920 kbps and DNI Type equals E1-CCS or
E1-CAS then channels cannot be programmed. The DNI?
Command will display all 'x'in the time-slot positions.