Mocomtech IP-Enabled M&C Network Hardware User Manual


 
CiM-25/600L IP Enabled M&C Rev. 1
Operation CD/CIM25600L.IOM
31
3.5.1.8 CHANGE READ ONLY PASSWORD
Using the !RP command, the Administrator can change the Read/Only login Password.
The command protocol for this command is as follows:
Format: !RP <string>
Where: <string> can be any alphanumeric string of length 4 to 10 characters
Query Format: !RP ?
Response: !RP <string>
Note:
Changes made via this command do not become active until the user has sent a !EE
command to commit the changes to EEPROM of the CiM-25.
3.5.1.9 ENABLE OR DISABLE PING
Using the !PG command, the Administrator can either enable or disable PING. The
command protocol for this command is as follows:
Format: !PG <state>
Where: 0 = Disabled, 1 = Enabled
Query Format: !PG ?
Response: !PG <state>
Note:
Changes made via this command do not become active until the user has sent a !EE
command to commit the changes to EEPROM of the CiM-25.
3.5.1.10 COMMIT CHANGES TO EEPROM
Using the !EE command, the Administrator can commit any previously commanded
changes to EEPROM. This will store the new operating parameters and automatically do
a warm reboot of the CiM-25/600L. The command protocol for this command is as
follows:
Format: !EE