Mocomtech IP-Enabled M&C Network Hardware User Manual


 
CiM-25/600L IP Enabled M&C Rev. 1
Operation CD/CIM25600L.IOM
30
3.5.1.5 CHANGE READ/WRITE NAME
Using the !WN command, the Administrator can change the Read/Write login Name. The
command protocol for this command is as follows:
Format: !WN <string>
Where: <string> can be any alphanumeric string of length 4 to 10 characters
Query Format: !WN ?
Response: !WN <string>
Note:
Changes made via this command do not become active until the user has sent a !EE
command to commit the changes to EEPROM of the CiM-25.
3.5.1.6 CHANGE READ/WRITE PASSWORD
Using the !WP command, the Administrator can change the Read/Write login Password.
The command protocol for this command is as follows:
Format: !WP <string>
Where: <string> can be any alphanumeric string of length 4 to 10 characters
Query Format: !WP ?
Response: !WP <string>
Note:
Changes made via this command do not become active until the user has sent a !EE
command to commit the changes to EEPROM of the CiM-25.
3.5.1.7 CHANGE READ ONLY NAME
Using the !RN command, the Administrator can change the Read Only login Name. The
command protocol for this command is as follows:
Format: !RN <string>
Where: <string> can be any alphanumeric string of length 4 to 10 characters
Query Format: !RN ?
Response: !RN <string>
Note:
Changes made via this command do not become active until the user has sent a !EE
command to commit the changes to EEPROM of the CiM-25.