Monarch 9835 Printer User Manual


 
Status2
B- Field Type
represents the MPCLII field that the error
occurred on. If the packet has no fields,
Status2 A will be replicated. If the error
occurs before the field is identified a question
mark is sent. Since the batch data is
variable, a
D
is sent to indicate data.
Status2
C- Field Number
represents the field number within each
packet. The packet header is the first field
and each subsequent field is indicated by the
field separator.
Status2
D- Parameter
represents the parameter within the field that
the error occurred. The numbering begins
after the field identifier.
Status2
E- Error Number
is the error that coincides with the error
numbers presented in Chapter 8, "Diagnostics
and Errors."
"FMT-1/BCH-2"
The format or batch number is returned.
If more than one error occurred then only the
most serious error will be acknowledged.
{J,"","F,B,4,6,33","FMT-1","BCH-2"}
Indicates that an error occurred on a bar code (
B
) field within a
format (
F
) packet. The bar code field is the fourth (
4
) field in the
packet. The error occurred in the sixth (
6
) parameter of the field.
Error number
33
means the bar code density is invalid.
To clear an error, press
CLEAR (ESCAPE/CLEAR)
or
ENTER
(ENTER/PAUSE)
, depending on your printer. An ENQ can also
clear errors numbered less than 500. Once the error is corrected,
a job request can be sent. The printer cannot accept another job
request until the error is resolved.
Status Polling