Monarch 9835TM Printer User Manual


 
9820/9830/9835 Service Manual Printer Error/Status Codes
TC9830SM Rev. B 7/98 Confidential July 199844
010
Field ID number is outside range 0 to 999.
011
Field length exceeds 2710.
012
Row field position is greater than maximum stock dimension.
013
Column field position is greater than maximum stock dimension.
014
Font style must be 1, 2, 3, 4, 10, 11, 15, 16, 17, 18, or 50.
015
Character rotation must be 0 (0 degree), 1 (90 degree), 2 (180 degree), or 3 (270 degree).
016
Field rotation must be 0 (0 degree), 1 (90 degree), 2 (180 degree), or 3 (270 degree).
017
Field restriction must be V (variable) or F (fixed).
018
Code page selection defined in field must be 0 (Internal), 1 (ANSI), 2 (DOS 437), or 3 (DOS 850).
020
Vertical magnification must be 1 to 7 or 4 to 90 points for scalable font.
021
Horizontal magnification must be 1 to 7 or 4 to 90 points for scalable font.
022
Color must be A, B, D, E, F, N, O, R, S, T, or W.
023
Intercharacter gap must be 0 to 99 dots.
024
Field justification must be B (balanced), C (centered), E (end), L (left), or R (right).
025
String length is outside range 0 to 2710.
030
Bar code height must be at least 20 (English), 51 (Metric), 40 (Dots), and within supply dimensions.
031
Human readable option must be:
0
default
1
no CD or NS
5
NS at bottom, no CD
6
CD at bottom, no NS
7
CD and NS at bottom
8
no text
032
Bar code type is invalid.
033
Bar code density is invalid.
040 Line thickness must be 0 to 99 dots.
041 Line direction must be 0, 90, 180, or 270.
042
End row is invalid. Line segment or box end row is defined outside of printable area.
043
End column is invalid. Line segment or box end column is defined outside of printable area.
044
Dot pattern for line or box must be "".
045
Line length is defined beyond maximum length.
046 Line type must be S (segment) or V (vector).
051 Imaging mode in graphic header must be 0.
101
The format referenced by batch is not in memory.
102 Print quantity is outside range 0 to 32000.