Moxa Technologies 5400 Series Network Card User Manual


 
NPort 5400 Series User’s Manual Web Console Configuration
5-20
is specified in milliseconds and must be larger than 10 ms.
If the user wants to send a series of characters in a packet, the serial device attached to the NPort
should send characters without time delay larger than Force Transmit timeout between characters
and the total length of data must be smaller than or equal to the NPort’s internal buffer size. The
serial communication buffer size of the NPort is 1 Kbytes per port.
Destination IP address 1
Setting Factory Default Necessity
IP address or Domain Address
(E.g., 192.168.1.1)
None Required
Allows the NPort to connect actively to the remote host whose address is set by this parameter.
Destination IP address 2/3/4
Setting Factory Default Necessity
IP address or Domain Address
(E.g., 192.168.1.1)
None Required
Allows the NPort to connect actively to the remote host whose address is set by this parameter.
ATTENTION
Up to 4 connections can be established between the NPort and hosts. The connection speed or
throughput may be low if one of the four connections is slow, since the slow connection will
slow down the other 3 connections.
ATTENTION
The “Destination IP address” parameter can use both IP address and Domain Name. For some
applications, the user may need to send the data actively to the remote destination domain name.
Designated Local Port 1/2/3/4
Setting Factory Default Necessity
TCP Port No.
5011 (Port 1)
5012 (Port 2)
5013 (Port 3)
5014 (Port 4)
Required
Connection control
Setting Factory Default Necessity
Startup/None,
Any Character/None,
Any Character/Inactivity Time,
DSR ON/DSR OFF,
DSR ON/None,
DCD ON/DCD OFF,
DCD ON/None
Startup/None Required
The meaning of each of the above settings is given in the table below. In general, both the Connect
condition and Disconnect condition are given.