Moxa Technologies 5400 Series Network Card User Manual


 
NPort 5400 Series User’s Manual Web Console Configuration
5-25
Reverse Telnet Mode
TCP alive check time
Setting Factory Default Necessity
0 to 99 min 0 Optional
Specifies the time slice for checking if the TCP connection is alive. If no response, the NPort 5400 will
disconnect the original connection.
Inactivity time
Setting Factory Default Necessity
0 to 65535 ms 0 Optional
Idle time setting for auto-disconnection. 0 min. means it will never disconnect.
Local TCP port
Setting Factory Default Necessity
1 to 65535 4001 Optional
Each of the NPort’s serial ports is mapped to a TCP port. To avoid conflicts with TCP ports, set port
numbers to 4001 for port1, 4002 for port 2, etc. (like the default values).
Map <CR-LF>
Setting Factory Default Necessity
CR, LF, or CR-LF CR-LF Optional
If data received through the NPort 5400’s Ethernet port is sent using the “enter” command, the data will
be transmitted out the serial port with an added
(1) “carriage return + line feed” if you select the <CR-LF> option
(i.e., the cursor will jump to the next line, and return to the first character of the line)
(2) “carriage return” if you select the <CR> option
(i.e., the cursor will return to the first character of the line)
(3) “line feed” if you select the <LF> option.
(i.e., the cursor will jump to the next line, but not move horizontally)