2-2 Intellio C218Turbo /PCI User's Manual
Step 7: Connect one of the connection box/cable (also adapter if required) detailed
in the next Section.
Step 8: Power on PC and BIOS will automatically set the IRQ and memory
address.
Note ! Each board must occupy one unique IRQ and one unique memory
address, which are assigned by PCI BIOS automatically.
However,
you may select the free IRQ number manually via PC's BIOS setup for
PCI slot, but normally this method is not available for memory. The
possible IRQ numbers are 2, 3, 4, 5, 9, 10, 11, 12, and 15.
Step 9: Proceed with software installation detailed in the next Chapter
¡§Software Installation”.
Installing Connection Option Opt8x
Connect the Intellio C218Turbo/PCI with the one of the following connection
options. Then you can connect your modem, serial printer, PC COM1/2, bar code
reader, POS, instrument or any other serial devices to the DB25/DB9 connectors.
Refer to Chapter “Connection Option (Opt8x) and Cable Wiring” for RS-232/RS-
422/RS-485 cable wiring.
Opt8A/Opt8B/Opt8S
Hold one end of the DB62 cable and plug it into the DB62 connector on the bracket
of the
Intellio C218Turbo/PCI. Carefully screw it until it is tight. Then plug the
other end of the cable to the RS-232 connection box's DB62 connector. Both ends of
the cable are identical.