Moxa Technologies Moxa EtherDevice Switch Switch User Manual


 
EDS-726 Series User’s Manual Featured Functions
3-41
To configure EDS-726 VLANs, use the VLAN Port Setting page to configure the ports.
Port Type
Setting Description Factory Default
Access This port type is used to connect single devices without
tags.
Trunk Select “Trunk” port type to connect another 802.1Q
VLAN aware switch or another LAN that combines
tagged and/or untagged devices and/or other
switches/hubs.
Access
ATTENTION
For communication redundancy in the VLAN environment, set “Redundant Port,” “Coupling
Port,” and “Coupling Control Port” as “Trunk Port,” since these ports act as the “backbone” to
transmit all packets of different VLANs to different EDS-726 units.
Management VLAN ID
Setting Description Factory Default
VLAN ID
ranges from
1 to 4094
Set the management VLAN of this EDS-726. 1
Port PVID
Setting Description Factory Default
VID range from 1
to 4094
Set the port default VLAN ID for untagged devices that
connect to the port.
1
Port Fixed VLAN List (Tagged)
Setting Description Factory Default
VID range from 1
to 4094
This field will be active only when selecting the “Trunk”
port type. Set the other VLAN ID for tagged devices that
connect to the “Trunk” port. Use commas to separate
different VIDs.
None
Port Forbidden VLAN List
Setting Description Factory Default
VID range from 1
to 4094
This field will be active only when selecting the “Trunk”
port type. Set the VLAN IDs that will not be supported
by this trunk port. Use commas to separate different
VIDs.
None