Moxa Technologies Moxa EtherDevice Switch Switch User Manual


 
EDS-726 Series User’s Manual Featured Functions
3-60
System Event Warning Relay output is triggered when…
Power Transition (OnÆOff) EDS-726 is powered on.
Power Transition (OffÆOn) EDS-726 is powered down.
DI1 (OnÆOff) Digital Input 1 is triggered by on to off transition
DI1 (OffÆOn) Digital Input 1 is triggered by off to on transition
DI2 (OnÆOff) Digital Input 2 is triggered by on to off transition
DI2 (OffÆOn) Digital Input 2 is triggered by off to on transition
Port Event Warning e-mail is sent when…
Link-on The port is connected to another device.
Link-off
The port is disconnected (e.g., the cable is pulled out,
or the opposing device shuts down).
Traffic-Overload
The port’s traffic surpasses the Traffic-Threshold for
that port (provided this item is Enabled).
Traffic-Threshold (%)
Enter a nonzero number if the port’s Traffic-Overload
item is Enabled.
Traffic-Duration (sec.)
A Traffic-Overload warning is sent every
Traffic-Duration seconds if the average
Traffic-Threshold is surpassed during that time
period.
NOTE
The Traffic-Overload, Traffic-Threshold (%), and Traffic-Duration (sec) Port Event items
are related. If you Enable the Traffic-Overload event, then be sure to enter a nonzero
Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds.
Override relay alarm settings
Click the checkbox to override the relay warning setting temporarily. Releasing the relay output
will allow administrators to fix any problems with the warning condition.
Relay Alarm List
Use this table to see if any relay alarms have been issued.