Multi-Tech Systems MT5634ZPW-PCI Network Card User Manual


 
MT5634ZPW-PCI
51
3 AT Commands, S-Registers and Result Codes
Register Unit Range Default Description
S42
decimal 0–1 1 Enables/disables the 56K auto
rate. Retrain and fallback are
disabled in data mode. 0 = dis-
able; 1 = enable.
S43
decimal 0–1 1
For testing and debugging only.
Enables/disables V.32bis start-up
auto mode operation. 0 = disable;
1 = enable.
S48
decimal 7 or 128 7 The following chart lists the S36
and S48 configuration settings
necessary to negotiate certain
types of connections.
S89
seconds 0, 5–255 10 Sets the length of time in the off-line
command mode before the modem
goes into standby mode. A value
of zero prevents standby mode; a
value of 1–4 sets the value to 5.
S108
decimal 0-3, 6,7 6 Selects the digital loss if using the
modem thru a PBX line. The
default value is -6dB loss, the
value used when calling from a
typical POTS line long distance.