National Instruments NI UES-3880 Switch User Manual


 
11
Specifications
Technology
Standards IEEE802.3, 802.3u, 802.3x
Forward and Filtering
Rate
148810 pps
Packet Buffer Memory 256 KB
Processing Type
Store and Forward, with IEEE802.3x full duplex,
back pressure flow control
Address Table Size 1K uni-cast addresses
Latency Less than 5 μs
Interface
RJ45 Ports
10/100BaseT(X) auto negotiation speed, F/H duplex
mode, and auto MDI/MDI-X connection
LED Indicators Power, Fault, 10M, 100M
DIP Switch Port break alarm mask
Alarm Contact
One relay output with current carrying capacity of
1A @ 24 VDC
Power
Input Voltage 12 to 48 VDC, redundant inputs
Input Current @ 24VDC 0.25 A
Connection Removable “6-pin” Terminal Block
Overload Current
Protection
1.1 A
Reverse Polarity
Protection
Present
Mechanical
Casing IP30 protection, metal case
Dimensions
53.6 × 135 × 105 mm (W × H × D)
Weight 0.63 kg
Installation DIN-rail, Wall Mounting
Environmental
Operating Temperature -40 to 75ºC (-40 to 167ºF)
Storage Temperature -40 to 85ºC (-40 to 185ºF)
Ambient Relative
Humidity
5 to 95% (non-condensing)
Regulatory Approvals
Safety
UL60950-1, CSA C22.2 No. 60950-1, EN60950-1,
TUV
Hazardous Location UL/cUL Class I, Division 2, Groups A, B, C, and D
EMI FCC Part 15, CISPR (EN55022) class A
EMS
EN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 3
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
Operating Shock 15g, half-sine, 11 ms pulse
Operating Vibration 10 Hz to 150 Hz, 1 grms