National Instruments PXI-846x Computer Hardware User Manual


 
Appendix C Cabling Requirements for PXI-8461 High-Speed CAN
© National Instruments Corporation C-7 PXI-846x and NI-CAN for Windows NT
Cabling Example
Figure C-6 shows an example of a cable to connect two CAN devices. For
the internal power configuration, no V+ connection is required.
Figure C-6.
Cabling Example
9-Pin
D-Sub
9-Pin
D-Sub
CAN_H
CAN_L
Shield
V+
V+
V
V
5-Pin
Combicon
5-Pin
Combicon
Pin 7Pin 4 Pin 7 Pin 4
Pin 2 Pin 2
Pin 5 Pin 3
Pin 9 Pin 5
Pin 3 Pin 1
Pin 2Pin 2
Pin 5Pin 3
Pin 9Pin 5
Pin 3Pin 1
120
120
Power
Connector