NEC N8100-1062F Server User Manual


 
4-16 Configuring Your Server
Option Parameter Description Your Setting
Post Error Pause Disabled
[Enabled]
Specify whether to stop the POST once
at the end of POST if an error occurs
during the POST.
AC-LINK Stay Off
[Last State]
Power On
Specify the state of power when the AC
power to the server is turn off once and
then on.
Power On Delay
Time (Sec)
[0] - 255 Specify the power on delay time within
the range between 0 and 255 seconds.
The time specified is valid when "Power
On" or "Last State" is specified for AC
LINK.
Platform Event
Filtering
[Disabled]
Enabled
This item becomes meaningless when
the notification feature of remote
management card (RMC) is enabled.
[ ]: Factory-set
IMPORTANT: To power on the server from the UPS (Uninterruptible
Power Supply), select [Server] - [AC LINK] - [Power On].
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC LINK."
Setting of AC LINK
System status before AC power off
Stay Off Last State Power On
Operating Off On On
Aborting (DC power being off also) Off Off On
Forced shutdown Off Off On
* Press the power switch continuously for four seconds or longer. This forcibly turns off the
power.