Network Equipment Technologies 100 Switch User Manual


 
10003137.00 Rev.1
2-4 Connecting PAP to an ISDN interface module
Connecting PAP to an ISDN interface module
BRMN, BRMT and early IPMN and IPMT
You must place the PrimeSwitch PAP Module panel in the slot immediately to the right
of the ISDN interface module that you want to monitor, with the connector located at
the top. If necessary, rearrange the modules in the PrimeSwitch to clear the slot on the
right hand side of the ISDN interface module. Note that you must update the
configuration of the PrimeSwitch to reflect the new arrangement of modules.
Connect the 10-way IDC connector on the PrimeSwitch PAP Module panel to the 10-way
header located just above the RJ-45 socket on the ISDN interface module. The red
conductor of the ribbon cable must be on the top.
Place the panel into the vacant slot and tighten the screws located on the top and bottom
of the panel.
Later IPMN and IPMT
These modules have a 9-way socket on the front panel to connect to PAP.
QBRM and DTM
The QBRM and DTM have a 9-way socket on the front panel to connect to PAP. This PAP
connection services all 4 interfaces.