Nortel Networks 60-12T Switch User Manual


 
Installation and Reference for the BayStack 60-12T/60-24T 10/100 Ethernet Hubs
3-6
206378-A
Verifying Port Status
You can check the status of each cable connection by viewing the port status
indicators shown in Figure 3-2
and described in Table 3-3.
Figure 3-2. Port Status LEDs
Table 3-3 describes the light and color indications of port status LEDs.
Table 3-3. Port Status LED Descriptions
LED State Indication
Power On (green) The hub is receiving power.
Collision Flashing (yellow) A packet collision occurred in the 10/100 Mb/s domain.
Activity Flashing (green) The port is receiving 10/100 Mb/s traffic.
Partition On (yellow) The port has been partitioned from the network.
Link 10/100M On (green) The port has established a valid 100 Mb/s network connection.
On (yellow) The port has established a valid 10 Mb/s network connection.