Nortel Networks NN43001-318 Network Card User Manual


 
Installing ISDN BRI hardware for line applications 33
Table 5 "NT8D37 IPE moduleSILC and UILC pair-terminations for
connectors A, E, K, R (12-cable configuration)" (page 33) shows
pair-terminations for connectors.
Table 5
NT8D37 IPE module
SILC and UILC pair-terminations for connectors A, E, K, R (12-cable configuration)
Port signals
I/O panel connectors
SILC UILC Pairs Pair color
AEKR
Card
port
0Tx - / 0Tx +
0Rx + / 0Rx -
0T / 0R 26 / 1
27 / 2
W-BL / BL-W
W-O / O-W
s
lot
0
slo
t4
slo
t8
s
lot
12
0
1Tx - / 1Tx +
1Rx + / 1Rx -
1T / 1R 28 / 3
29 / 4
W-G / G-W
W-BR / BR-W
1
2Tx - / 2Tx +
2Rx + / 2Rx -
2T / 2R 30 / 5
31 / 6
W-S / S-W
R -BL / BL-R
2
3Tx - / 3Tx +
3Rx + / 3Rx -
3T / 3R 32 / 7
33 / 8
Rx-O / O-R
R -G / G-R
3
4Tx - / 4Tx +
4Rx + / 4Rx -
4T / 4R 34 / 9
35 / 10
R-BR / BR-R
R-S / S-R
4
5Tx - / 5Tx +
5Rx + / 5Rx -
5T / 5R 36 / 11
37 / 12
BK-BL / BL-BK
BK-O / O-BK
5
6Tx - / 6Tx +
6Rx + / 6Rx -
6T / 6R 38 / 13
39 / 14
BK-G / G-BK
BK-BR / BK-BR
6
7Tx - / 7Tx +
7Rx + / 7Rx -
7T / 7R 40 / 15
41 / 16
BK-S / S-BK
Y-BL / BL-Y
7
Table 6 "NT8D37 IPE moduleSILC and UILC pair-terminations for
connectors B, F, L, S (12-cable configuration)" (page 33) shows
pair-terminations for connectors B, F, L, S.
Table 6
NT8D37 IPE module
SILC and UILC pair-terminations for connectors B, F, L, S (12-cable configuration)
Port signals
I/O panel connectors
SILC UILC Pairs Pair color
BF L
S
Card
port
0Tx - / 0Tx +
0Rx + / 0Rx -
0T / 0R 26 / 1
27 / 2
W-BL / BL-W
W-O / O-W
s
lot
1
slo
t5
slo
t9
s
lot
13
0
1Tx - / 1Tx +
1Rx + / 1Rx -
1T / 1R 28 / 3
29 / 4
W-G / G-W
W-BR / BR-W
1
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318 01.02 Standard
Release 5.0 20 June 2007
Copyright © 2003-2007, Nortel Networks
.