Nortel Networks NN43001-318 Network Card User Manual


 
Voice calls 93
Call Join two separate parties on the terminal
disconnect from the Conference
Procedure 31
Perform an ISDN BRI Conference test
Step Action
The same procedures can be used to test ISDN BRI NI-1 or ETSI
Conference.
1
In the DSL configuration in LD 27, set PRID = 6 to select the National
ISDN-1 protocol, or set PRID = 2 for the ETSI protocol.
2
In the TSP configuration in LD 27, define conference under FEATID:
FEATID aaa mmm <nnn>, where
aaa = A03 (3-party conference) or A06 (6-party conference)
mmm = feature activation ID (0 - 127)
nnn = feature indication ID (0 - 127) (If nnn is not entered, it is
assumed
to be the same as mmm)
3
Select National ISDN-1 or ETSI protocol on the ISDN BRI terminal if
signaling type/protocol is configurable.
4
On the ISDN BRI terminal, configure Conference. This procedure
largely depends on the implementation of feature key management
on individual terminals. In general:
a. The terminal provides Conference as a selectable feature to be
programmed on a hard/soft key. For example, on a soft key
on an M5317TDX, select FA to be FCC; on a hard key on an
M5209TDcp, select CONF.
b. The Conference key number selected on the ter minal must
correspond to the feature activation ID entered for the TSP in
LD 27.
5
Configure at least two DN appearances on the ISDN BRI terminal.
On some ISDN BRI terminals, the second DN appearance allows
the user to initiate the second call.
6
Place an outgoing call from the ISDN BRI terminal.
7
After the call is established, press the Conference key. The first call
is put on hold automatically; a second key is lit to allow the user
to place the second call.
8
Place another outgoing call from the second key.
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318 01.02 Standard
Release 5.0 20 June 2007
Copyright © 2003-2007, Nortel Networks
.